Honeywell keeps control. LoRaWAN makes it think ahead.
We fuse your existing Honeywell BMS with a dense mesh of LoRaWAN sensors on the IoTLogiq platform — occupancy, people-counting, CO2, temperature, humidity, leak, tilt, airflow and dual-pressure — to drive proactive circulation, ventilation and cooling in anticipation of modeled occupancy.
- 11
- Fused sensor channels
- 7
- Platforms integrated
- 2
- Ingestion paths
- 124
- MCP tools (BOB AI)
The integration
Four layers, from field wire to proactive action
Honeywell stays the system of record for control. IoTLogiq becomes the system of intelligence — enriching, modeling and anticipating.
Honeywell BMS + LoRaWAN mesh
Honeywell Niagara/JACE and Experion PKS run the plant as they do today. A parallel LoRaWAN mesh on ChirpStack adds granular room-level awareness Honeywell never had.
- Niagara BACnet/IP
- Experion OPC-UA
- Siemens Desigo
- ChirpStack sensors
IoTLogiq 4.3 + Edge gateway
Two interchangeable paths. IoTLogiq 4.3 speaks BACnet natively for direct acquisition; the IoTLogiq Edge gateway handles OPC-UA, LoRaWAN and legacy protocols where a local hop is needed.
- IoTLogiq native BACnet
- IoTLogiq Edge gateway
- Protocol normalization
- Store-and-forward
One asset & point graph
Every field point — regardless of vendor or protocol — maps to a single canonical IoTLogiq key. Sensor fusion and control logic operate on this normalized graph, not on vendor tags.
- Unified point keys
- Mapping Studio
- Multi-tenant scoping
- Write-back guards
Fusion, prediction, write-back
The fusion engine turns raw channels into comfort, efficiency and cost. Modeled occupancy drives proactive setpoints written safely back into Honeywell. BOB AI and n8n orchestrate the rest.
- Predictive control
- BOB AI (MCP)
- n8n / rule chains
- Maximo work orders
Option A — sensor fusion
Eleven LoRaWAN channels fuse into every Honeywell decision
Honeywell owns the actuators. Our sensors tell it what the building is actually doing — room by room — so control becomes anticipatory instead of reactive.
Fused inputs → control effect
- Occupancy (PIR)Setback / activation
- People countingDemand-based ventilation
- CO2 air qualityFresh-air damper %
- Temp + humiditySetpoint trim
- Leak detectionIsolation + work order
- Tilt (roof vents)Vent fault detection
- AirflowFan speed validation
- Dual pressureFilter / duct health
- Light controlZone scene + HVAC pairing
- Door monitoringLeakage compensation
- Window monitoringHVAC lockout
A single control intent per zone, reconciled against Honeywell's own logic and written back only through guarded, auditable commands.
Temperature, humidity and CO2 held in band where people actually are.
No conditioning empty rooms; drive matched to real occupancy.
kWh and $/hr attributed per zone, per tenant, per behaviour.
Pre-cool, pre-ventilate and pre-circulate ahead of modeled arrival.
Integration strategy
Two ingestion paths, one canonical model
Because IoTLogiq 4.3 can now speak BACnet, we pick the shortest safe path per system — and everything still lands in the same IoTLogiq point graph.
IoTLogiq 4.3 direct BACnet
IoTLogiq 4.3 ships a native BACnet/IP connector. Where Honeywell and Siemens controllers are reachable on the OT network, IoTLogiq acquires points directly — fewer hops, lower latency, less to maintain.
- Native BACnet/IP + COV
- Lowest latency
- No extra gateway host
- IoTLogiq rule chains on-box
IoTLogiq Edge gateway
A local edge runtime with OPC-UA, LoRaWAN and legacy protocol clients. It normalizes, buffers and forwards — ideal for Experion, segmented networks, or sites needing store-and-forward resilience.
- OPC-UA + LoRaWAN + Modbus
- Store-and-forward
- Protocol translation
- Runs at the site
Connected systems
One integration fabric across vendors
Honeywell Niagara / JACE
BACnet/IP building automation
Honeywell Experion PKS
OPC-UA process control
Siemens Desigo CC
BACnet building management
ChirpStack LoRaWAN
Wireless sensor enrichment
IBM Maximo EAM
Automated work orders
IoTLogiq 4.3
Acquisition + rule chains
BOB AI (MCP, 124 tools)
Natural-language diagnostics
n8n
Event-driven automation
See it running in the operations console
Live SCADA, sensor fusion, predictive control, mapping studio and connector health — all in explicit demo mode, ready to point at your IoTLogiq 4.3 deployment.